1Z0-066 Latest Test Duration & Oracle Free 1Z0-066 Learning Cram - Oracle Database 12C: Data Guard Administrator - Royalholidayclubbed

 

Home

My $18,000 Timeshare Story

Objectives

The Power Of Two

 

Other People's Stories

Important Links

  

Timeshare Articles

  

RHC Destination Reviews

  

Who Is Harpy?

Write To Harpy

Throw Harpy A Fish!

  

The Timeshare Club

 

Bookmark this site

 

Need More Information?

Actually we eliminate the barriers blocking you from our 1Z0-066 Latest Test Duration practice materials. All types of our 1Z0-066 Latest Test Duration exam questions are priced favorably on your wishes. Obtaining our 1Z0-066 Latest Test Duration study guide in the palm of your hand, you can achieve a higher rate of success. You have tried all kinds of exam questions when others are still looking around for 1Z0-066 Latest Test Duration exam materials, which means you have stayed one step ahead of other IT exam candidates. 1Z0-066 Latest Test Duration exam software provided by our Royalholidayclubbed consists of full exam resources will offer you a simulation of the real exam atmosphere of 1Z0-066 Latest Test Duration. If you have made up your mind to get respect and power, the first step you need to do is to get the 1Z0-066 Latest Test Duration certification, because the certification is a reflection of your ability.

Oracle Database 12c 1Z0-066 Also, we have benefited from such good behavior.

More about 1Z0-066 - Oracle Database 12c: Data Guard Administrator Latest Test Duration Exams Dumps: If you want to know more about our test preparations materials, you should explore the related 1Z0-066 - Oracle Database 12c: Data Guard Administrator Latest Test Duration exam Page. It is known to us that preparing for the exam carefully and getting the related certification are very important for all people to achieve their dreams in the near future. It is a generally accepted fact that the Real Question 1Z0-066 On The Exam exam has attracted more and more attention and become widely acceptable in the past years.

Our 1Z0-066 Latest Test Duration training materials are compiled by professional experts. All the necessary points have been mentioned in our 1Z0-066 Latest Test Duration practice engine particularly. About some tough questions or important points, they left notes under them.

Oracle 1Z0-066 Latest Test Duration - Just come and buy it!

The dynamic society prods us to make better. Our services on our 1Z0-066 Latest Test Duration exam questions are also dependable in after-sales part with employees full of favor and genial attitude towards job. So our services around the 1Z0-066 Latest Test Duration training materials are perfect considering the needs of exam candidates all-out. They bravely undertake the duties. Our staff knows our 1Z0-066 Latest Test Duration study quiz play the role of panacea in the exam market which aim to bring desirable outcomes to you.

We believe if you compare our 1Z0-066 Latest Test Duration training guide with the others, you will choose ours at once. Our 1Z0-066 Latest Test Duration study materials have a professional attitude at the very beginning of its creation.

1Z0-066 PDF DEMO:

QUESTION NO: 1
You created a physical standby database PRODSBY1 from the primary database PROD using SQL and RMAN Which two are prerequisites for creating a Data Guard Broker configuration to manage these databases?
A. The standby database must have supplemental logging enabled.
B. The primary database must have FORCE LOGGING enabled
C. The DG_BROKER_START parameter must be set to TRUE for both database
instances.
D. The primary database must have supplemental logging enabled.
E. A local net service name to enable connectivity to the PRODSBY1 database instance must be defined on the primary database host.
Answer: B,C

QUESTION NO: 2
You are required to change the Data Guard Configuration protection mode from
MAXPERFORMANCE to MAXAVAJLABILITY using Enterprise Manager Cloud Control
Which two are true about this change?
A. If the primary database cannot write its redo to at least one synchronized standby database, then the protection level remains unchanged.
B. The primary database instance will remain up and running, if it cannot write redo to at least one synchronized standby database.
C. Transactions will not commit until all redo data needed to recover those transactions are written to the online redo log, and to the standby redo log on at least one synchronizes standby database.
D. Fast start failover can be enabled when making the chance.
E. Real time apply will be automatically turned on.
Answer: B,C

QUESTION NO: 3
A customer has these requirements for their potential Data Guard implementation:
1. Zero data loss must still be guaranteed through the loss of any one configuration component.
2 The primary database must be protected against a regional disaster
3 . Performance overheads on the primary should be minimized as much as possible given these requirements.
4. Downtime on the primary database for any reason must be kept to a minimum.
Components referred to in the broker commands are:
Which Data Guard broker commands are needed to implement these requirements?
A. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1
SYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (pnma: physt2 SYNC)';
EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY
B. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1 ASYNC)'; EDIT
FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima physt FASTSYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXPROTECTION
C. EDIT DATABASE prima SET PROPERY REDOROUTES' (LOCAL: fs1 SYNC)'; EDIT
FAR_SYNCfs1 SET PROPERTY REDORUOTES=' (prima physt ASYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
D. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES= (LOCAL: fs1.
FASTSYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima: physt2
ASYNC)'; EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
Answer: A

QUESTION NO: 4
Examine the Data Guard configuration:
Configuration Status: SUCCESS
Which two are true?
A. The observer must run on host ol5.example com and is currently not running.
B. The observer will reinstate Sheep automatically after a failover, if required.
C. The observer will mark another standby database as the failover target if the original failover target becomes unavailable.
D. The observer will detect if the primary database is unable to accept new connections
E. The former primary database will not be reinstated automatically alter a failover.
Answer: B,E

QUESTION NO: 5
Which two Data Guard features require the use of flashback database by the broker?
A. Read-Mostly physical standby implementations
B. Far Sync Instances
C. Fast-Start Failover
D. Real Time Query
E. Snapshot Standby databases
Answer: C,E

As we know, our products can be recognized as the most helpful and the greatest HP HP2-I78 study engine across the globe. Our {Fortinet FCP_ZCS-AD-7.4 certification material get to the exam questions can help users in the first place, and what they care about the test information, can put more time in learning a new hot spot content. Linux Foundation CKA - Service is first! At the same time, as long as the user ensures that the network is stable when using our SAP C_FIORD_2502 training materials, all the operations of the learning material of can be applied perfectly. The experts in our company have been focusing on the Huawei H20-722_V1.0 examination for a long time and they never overlook any new knowledge.

Updated: May 28, 2022

 

Copyright © 2006-2007

by RHC.

All rights reserved.
Revised: 21 Oct 2007

 

---------------

Google
 
Web www.RoyalHolidayClubbed.com

If you don't find what you are looking for here

to help you resolve your timeshare scam or Royal Holiday problem

please write to us at:

harpy @ royalholidayclubbed.com

Link Partner Directory

Privacy Policy

www . Royal Holiday Clubbed . com

Related Posts

 

sitemap