Oracle 1Z0-066 Exam Practice certification exam is a high demand exam tests in IT field because it proves your ability and professional technology. To get the authoritative certification, you need to overcome the difficulty of 1Z0-066 Exam Practice test questions and complete the actual test perfectly. Our training materials contain the latest exam questions and valid 1Z0-066 Exam Practice exam answers for the exam preparation, which will ensure you clear exam 100%. You will have the opportunity to enjoy the best service from our company. In order to meet the need of all customers, there are a lot of professionals in our company. It is so cool even to think about it.

Oracle Database 12c 1Z0-066 It is never too late to learn new things.

Oracle Database 12c 1Z0-066 Exam Practice - Oracle Database 12c: Data Guard Administrator Our Oracle Database 12c: Data Guard Administrator exam prep has taken up a large part of market. 1Z0-066 Latest Test Cost exam questions have a very high hit rate, of course, will have a very high pass rate. Before you select a product, you must have made a comparison of your own pass rates.

The Oracle 1Z0-066 Exam Practice exam questions aid its customers with updated and comprehensive information in an innovative style. The 1Z0-066 Exam Practice exam simulator plays a vital role in increasing your knowledge for exam. The Royalholidayclubbed’ Oracle Testing Engine provides an expert help and it is an exclusive offer for those who spend most of their time in searching relevant content in the books.

Oracle 1Z0-066 Exam Practice - Please give us a chance to prove.

We provide online customer service to the customers for 24 hours per day and we provide professional personnel to assist the client in the long distance online. If you have any questions and doubts about the Oracle Database 12c: Data Guard Administrator guide torrent we provide before or after the sale, you can contact us and we will send the customer service and the professional personnel to help you solve your issue about using 1Z0-066 Exam Practice exam materials. The client can contact us by sending mails or contact us online. We will solve your problem as quickly as we can and provide the best service. Our after-sales service is great as we can solve your problem quickly and won’t let your money be wasted. If you aren’t satisfied with our 1Z0-066 Exam Practice exam torrent you can return back the product and refund you in full.

As you can see, we never stop innovating new version of the 1Z0-066 Exam Practice study materials. We really need your strong support.

1Z0-066 PDF DEMO:

QUESTION NO: 1
You created a physical standby database PRODSBY1 from the primary database PROD using SQL and RMAN Which two are prerequisites for creating a Data Guard Broker configuration to manage these databases?
A. The standby database must have supplemental logging enabled.
B. The primary database must have FORCE LOGGING enabled
C. The DG_BROKER_START parameter must be set to TRUE for both database
instances.
D. The primary database must have supplemental logging enabled.
E. A local net service name to enable connectivity to the PRODSBY1 database instance must be defined on the primary database host.
Answer: B,C

QUESTION NO: 2
A customer has these requirements for their potential Data Guard implementation:
1. Zero data loss must still be guaranteed through the loss of any one configuration component.
2 The primary database must be protected against a regional disaster
3 . Performance overheads on the primary should be minimized as much as possible given these requirements.
4. Downtime on the primary database for any reason must be kept to a minimum.
Components referred to in the broker commands are:
Which Data Guard broker commands are needed to implement these requirements?
A. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1
SYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (pnma: physt2 SYNC)';
EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY
B. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1 ASYNC)'; EDIT
FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima physt FASTSYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXPROTECTION
C. EDIT DATABASE prima SET PROPERY REDOROUTES' (LOCAL: fs1 SYNC)'; EDIT
FAR_SYNCfs1 SET PROPERTY REDORUOTES=' (prima physt ASYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
D. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES= (LOCAL: fs1.
FASTSYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima: physt2
ASYNC)'; EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
Answer: A

QUESTION NO: 3
Examine the Data Guard configuration:
Configuration Status: SUCCESS
Which two are true?
A. The observer must run on host ol5.example com and is currently not running.
B. The observer will reinstate Sheep automatically after a failover, if required.
C. The observer will mark another standby database as the failover target if the original failover target becomes unavailable.
D. The observer will detect if the primary database is unable to accept new connections
E. The former primary database will not be reinstated automatically alter a failover.
Answer: B,E

QUESTION NO: 4
Which two Data Guard features require the use of flashback database by the broker?
A. Read-Mostly physical standby implementations
B. Far Sync Instances
C. Fast-Start Failover
D. Real Time Query
E. Snapshot Standby databases
Answer: C,E

QUESTION NO: 5
You are required to change the Data Guard Configuration protection mode from
MAXPERFORMANCE to MAXAVAJLABILITY using Enterprise Manager Cloud Control
Which two are true about this change?
A. If the primary database cannot write its redo to at least one synchronized standby database, then the protection level remains unchanged.
B. The primary database instance will remain up and running, if it cannot write redo to at least one synchronized standby database.
C. Transactions will not commit until all redo data needed to recover those transactions are written to the online redo log, and to the standby redo log on at least one synchronizes standby database.
D. Fast start failover can be enabled when making the chance.
E. Real time apply will be automatically turned on.
Answer: B,C

In your every stage of review, our Splunk SPLK-1003 practice prep will make you satisfied. Oracle certification Juniper JN0-281 exam can give you a lot of change. IIA IIA-CIA-Part1-CN - Need any help, please contact with us again! In order to pass Oracle certification ISTQB CTAL-TM-001 exam disposably, you must have a good preparation and a complete knowledge structure. Pegasystems PEGACPLSA23V1 - Our questions and answers are based on the real exam and conform to the popular trend in the industry.

Updated: May 28, 2022

 

Copyright © 2006-2007

by RHC.

All rights reserved.
Revised: 21 Oct 2007

 

---------------

Google
 
Web www.RoyalHolidayClubbed.com

If you don't find what you are looking for here

to help you resolve your timeshare scam or Royal Holiday problem

please write to us at:

harpy @ royalholidayclubbed.com

Link Partner Directory

Privacy Policy

www . Royal Holiday Clubbed . com

Related Posts

 

sitemap